CygNet Measurement > FMS Explorer > Commands Menu > Running File Import Commands > Import: Configuration CSV

Configuring Import: Configuration CSV Commands

Use the Import File: Configuration CSV command to import comma-separated values (.csv) files containing configuration data into FMS. The imported configuration data can be applied to the device Node record for a specified date/time or for a date/time range. Prior to executing the import, you also have the option to configure and edit the .csv file to prepare it for successful importation into your CygNet Measurement system.

See FMS Commands and Import: Configuration CSV for more information about this command.

See Scheduling FMS Command Tasks in the MSS for more information about scheduling commands.

See FMS ActiveX Controls and CxHmiFms for more information about using commands via FMS ActiveX controls on CygNet Studio or CygNet Vision screens.

See CxFms for more information about scripting commands.

Preparing the CSV Import File

Include the appropriate column(s) to apply imported configuration records to a specified date/time or to a date/time range, as follows.

Imported configuration data is applied in the following manner, depending on the date/time(s) defined in the .csv file and the records present in the device.

Customizing the CSV Import File

You can also use an import definition file (.idf) to define details about how the items in your configuration .csv file are imported into FMS and how they will appear in the file. To do this, customize the column and data source settings using an .idf. See Using an Import Definition File for more information.

Command Definition Properties

The following command definition properties apply to Configuration CSV File Import commands.

Property Description

Command type

For system commands, this property will be read-only and will display the selected command type.

See FMS Commands for more information about command types.

Priority

Select a processing queue Priority for the command from the drop-down menu.

Options from least to greatest priority are as follows.

  • Low level
  • Medium level
  • High level
  • User initiated transaction
  • Admin initiated transaction

Default value is Low level processing queue priority.

Logging

Select a Logging level for the command results from the drop-down menu.

Options are as follows.

  • Low - displays errors
  • Medium - displays errors and warnings
  • High - displays errors, warnings, and status

Default value is Low level logging when scheduling a command in the MSS.

Default value is High level logging when creating or running an ad-hoc command in FMS Explorer.

Command Parameters

The following command parameters apply to Import: Configuration CSV commands, when creating or editing commands in FMS. See Configuration Import CSV Files for more information about setting up your configuration .csv file for import.

Parameter Value

Import file directory

Enter the directory location from which to import the file.

Type in the value or click ... to access the Browse for Folder dialog box, and browse to the directory location.

Note: The directory specified is relative to the computer hosting the FMS service.

This parameter is required.

Import file mask

If specified, only files meeting the file mask will be considered for import.

Type the file mask name.

Default file mask value is "*" (multiple character wildcard).

This parameter is optional.

Processed files retention (days)

If specified, the files that have been processed will be deleted after the specified number of days. If not specified, processed files will never be deleted.

Type the number of days.

This parameter is optional.

Unit set

If specified, select a unit set in which to view the data.

Options appear in the drop-down menu, which is populated by the unit sets defined in the service.

See Configuring Unit Set Definitions for more information.

This parameter is optional.

Notes:

If you do not specify the unit set with this parameter, units for each included value must be specified using an .idf file.

If you specify the unit set with this parameter AND in the .idf file, the value specified in the .idf file prevails, and overrides this setting. In this way, you may override individual unit values by setting them in the .idf file.

Recalculate affected history records

Select whether or not to recalculate history records affected by the configuration value change.

Options are as follows.

  • Yes
  • No
  • Energy only

If set to Yes, the system will automatically recalculate energy, volume and/or mass values for any historical records affected by the configuration change.

If set to No, the system will not recalculate any historical records, but configuration value changes will be saved.

If set to Energy only, the system will automatically recalculate energy values only, for any historical records affected by the configuration change, while preserving previous history edits.

If no historical records are affected, this parameter will be ignored.

This parameter is required.

Add devices to group

If specified, all devices with imported data will be added to the group. Type the name of the group to which the imported devices will be added.

Note: Nodes added to this group are added for the entire span of the Node or group (whichever is less).

Example

In the case of a gas quality import, you could execute a Send Gas Quality command to send GQ data from all imported files to the devices.

This parameter is optional.

Clear existing group entries

If specified, options are Yes or No.

If set to Yes, and a value has been specified for Add devices to group, any existing entries will be removed from the specified group before executing the command.

If set to No, the existing group entries will be retained when executing the command.

Note: Nodes cleared from this group are cleared for the entire span of the Node or group.

This parameter is optional.

Comments

If specified, the comments will be part of the audit record for the file import. Type comments regarding the import.

This parameter is optional.

Configuration Import CSV Files

Note: Prior to importing a configuration .csv file, the following conditions must be met for each Node for which you are importing data.

Use the following procedure to prepare a configuration import .csv file for import into FMS.

To Configure and Edit a Configuration Import CSV File

Once generated, you can edit the configuration import .csv file as follows, prior to importing it into FMS.

  1. Open a .csv file for your configuration import.
  2. Insert required (as noted) columns into your file, using your .csv editor. All required configuration import .csv columns are noted in the table below.
  3. Insert additional columns into your file, as desired. All available configuration import .csv columns are described or referenced in the tables below.
  4. Edit any configuration items desired (e.g. description, etc.) at this time, in preparation for importing the file to FMS.
  5. Save and Close the .csv file when you are done.

Configuration Import CSV Columns

Required Configuration Import CSV Columns

The following table lists the columns for which values must exist in the configuration import .csv file (as noted in each description) in order for the FMS import to succeed.

Column Description
Device The device name

This column is required.

ConfigDateTime The date/time for which to import and update the configuration record

 

Note: When EndDateTime is also defined, this value functions as the beginning date/time of a date range for which to update all records found.

This column is required.

eFMS_CFG_CALC_METHOD_PRIMARY The primary calculation method

Options are as follows.

  • 1 - AGA 3 1985
  • 2 - AGA 3 1992
  • 3 - AGA 7
  • 5 - AGA 9 (not supported)
  • 6 - AGA 11
  • 7 - VCone
  • 8 - AGA 5 (not supported)
  • 9 - ISO 9951 (not supported)
  • 10 - ISO 5167 (not supported)
  • 11 - Wafer Cone
  • 12 - AGA 3 2013

This column is required.

Note: If you already have this configuration value imported, this field may not be required.

eFMS_CFG_METER_TYPE The device type

Options are as follows.

  • 1 - Orifice
  • 2 - Positive (supported for liquid devices)
  • 3 - Turbine
  • 4 - Ultrasonic
  • 5 - Liquids (not supported)
  • 6 - Cone
  • 7 - Coriolis

This column is required.

Note: If you already have this configuration value imported, this field may not be required.

[as specified in an .idf] In the import definition file (.idf), additional columns may be identified as required="true" in order to perform the import.

See Using an Import Definition File for more information.

Back to top
Additional Configuration Import CSV Columns

Additional column headers can optionally be included in the configuration import .csv file. Columns can be included for any supported FMS configuration items for which you have data in your system.

The following table lists options for column headers that may be contained in your .csv file. The list is not complete; it is provided only for reference. See FMS Configuration Items for a complete list of configuration items which could also appear as column headers in your configuration import .csv file.

Column Description
EndDateTime The ending date/time of a date range. Any records that exist within the defined date range will be updated with the new configuration data.

 

Note: When specified, this value functions in conjunction with ConfigDateTime to define a date range for which to update all records found.

eFMS_CFG_CALC_METHOD_FPV Compressibility Calc Method

Options are as follows.

  • 1 - AGA 8 Gross 1
  • 2 - AGA 8 Gross 2
  • 3 - AGA 8 Detail
  • 4 - NX 19 GCN
  • 5 - NX 19 Complete
  • 6 - None
  • 7 - GERG (not supported)
eFMS_CFG_CALC_METHOD_DISCHARGE_COEFFICIENT Discharge Coefficient Calc Method

Options are as follows.

  • 1 - None
eFMS_CFG_CALC_METHOD_GAS_EXPANSION_FACTOR Gas Expansion Factor Method

Options are as follows.

  • 1 - None
eFMS_CFG_METER_TUBE_MATERIAL Meter Tube Material

Options are as follows.

  • 1 - Stainless steel (unspecified type)
  • 2 - Monel (valid for AGA 3 1985 or 1992 only)
  • 3 - Carbon steel
  • 4 - Unspecified
  • 5 - Stainless steel 304 (valid for AGA 3 2013 only)
  • 6 - Stainless steel 316 (valid for AGA 3 2013 only)
  • 7 - Monel 400 (valid for AGA 3 2013 only)

Note: This field is "Unspecified" for devices that do not return a material type value. In these cases, a (non-zero) thermal expansion coefficient value (eFMS_CFG_PIPE_COEFFICIENT_THERMAL_EXPANSION) is required for calculation to succeed.

eFMS_CFG_ORIFICE_PLATE_MATERIAL* Orifice Plate Material*

Options are as follows.

  • 1 - Stainless steel (unspecified type)
  • 2 - Monel (valid for AGA 3 1985 or 1992 only)
  • 3 - Carbon steel
  • 4 - Unspecified
  • 5 - Stainless steel 304 (valid for AGA 3 2013 only)
  • 6 - Stainless steel 316 (valid for AGA 3 2013 only)
  • 7 - Monel 400 (valid for AGA 3 2013 only)

Note: This field is "Unspecified" for devices that do not return a material type value. In these cases, a (non-zero) thermal expansion coefficient value (eFMS_CFG_ORIFICE_COEFFICIENT_THERMAL_EXPANSION) is required for calculation to succeed.

eFMS_CFG_CONE_MATERIAL Cone Material

Options are as follows.

  • 1 - Stainless steel
  • 2 - Monel
  • 3 - Carbon steel
  • 4 - Unspecified

Note: This field is "Unspecified" for devices that do not return a material type value. In these cases, a (non-zero) thermal expansion coefficient value (eFMS_CFG_CONE_COEFFICIENT_THERMAL_EXPANSION) is required for calculation to succeed.

eFMS_CFG_DP_TAPS_TYPE* DP Taps Type*

Options are as follows.

  • 1 - Flange
  • 2 - Pipe
eFMS_CFG_SP_TAP_LOCATION SP Tap Location

Options are as follows.

  • 1 - Upstream
  • 2 - Downstream
eFMS_CFG_SP_SENSOR_TYPE SP Sensor Type

Options are as follows.

  • 1 - Absolute
  • 2 - Gauge
eFMS_CFG_INTEGRAL_VALUE_VARIABLES Variables included in IV

Options are as follows.

  • 1 - (FT*DP[inh2o]*SP[psia])
  • 2 - (FT*DP[inh2o]*SP[psia])/T[R]
  • 3 - (FT*DP[inh2o]*SP[psia])/Gr
  • 4 - (FT*DP[inh2o]*SP[psia])/(T[R]*Gr))
  • 5 - None
  • 6 - (FT*DP[mBar]*SP[bar])
  • 7 - (FT*DP[mBar]*SP[bar])/T[K]
  • 8 - (DP[inh2o]*SP[psia])
  • 9 - (DP[inh2o]*SP[psia])/T[R]
  • 10 - (DP[inh2o]*SP[psia])/Gr
  • 11 - (DP[inh2o]*SP[psia])/(T[R]*Gr)
  • 12 - (DP[mBar]*SP[bar])
  • 13 - (DP[mBar]*SP[bar])/T[K]
eFMS_CFG_HEATING_VALUE_BASIS Heating Value Basis

Options are as follows.

  • 1 - Wet
  • 2 - Dry
  • 3 - As delivered
eFMS_CFG_FLUID_TYPE Fluid Type

Options are as follows.

  • 1 - Compressible
  • 2 - Noncompressible
eFMS_CFG_USE_LIVE_TEMP Use Live Temperature

Options are as follows.

  • 0 - No
  • 1 - Yes
eFMS_CFG_AGA3_EXPANDED_RANGE AGA 3 Expanded Range

Options are as follows.

  • 0 - No
  • 1 - Yes
eFMS_CFG_AGA8_EXPANDED_RANGE AGA 8 Expanded Range

Options are as follows.

  • 0 - No
  • 1 - Yes

See AGA 8 Data Ranges for more information.

eFMS_CFG_CUSTOM1 10 Custom configuration items are available to be mapped to supported items as desired.

See FMS Configuration Items for a complete list of all supported configuration items.

See Configuring Custom Device Data for more information about the configuration process.

eFMS_CFG_CUSTOM2
eFMS_CFG_CUSTOM3
eFMS_CFG_CUSTOM4
eFMS_CFG_CUSTOM5
eFMS_CFG_CUSTOM6
eFMS_CFG_CUSTOM7
eFMS_CFG_CUSTOM8
eFMS_CFG_CUSTOM9
eFMS_CFG_CUSTOM10

*Orifice

**Turbine

Back to top

Let us know how we can improve this topic.