CygNet Measurement > FMS Utilities > FMS Toolbox > Configuring and Editing CSV Files for FMS Import > GMR Data Items Units

GMR Data Items Units

FMS assigns an expected unit set to data coming from GMR. On occasion, GMR data could arrive with some data items using unit values other than what is expected. To adjust for this, you can define and specify an optional unit set override to correct the unit value inconsistencies.

The following EFM (electronic flow measurement) data item units list the expected unit values for the GMR unit set applied to data coming into the CygNet Measurement system from GMR.

GMR Unit Set

Expected GMR units for the following data item types are listed in the tables below.

Configuration Units

The following units apply to GMR configuration data items. Additional Shared Units apply to multiple data item types.

GMR Configuration Item Description

GMR Units

Atmospheric pressure psi (pound-force per square inch)
Base pressure psi (pound-force per square inch)
Base temperature F (degrees Fahrenheit)
Cone diameter in (inches)
Cone reference temperature F (degrees Fahrenheit)
Elevation ft (feet)
K factor - Volume p/MCF (pulses per thousand cubic feet)
Low flow cutoff - DP inH2O (inches of water)
Low flow cutoff - Flow rate CFH (cubic feet per hour)
Low flow cutoff - Pulse interval sec (seconds)
Meter tube inside diameter in (inches)
Meter tube reference temperature F (degrees Fahrenheit)
Orifice coefficient of thermal expansion in/in-F (inches per inch - Fahrenheit)
Orifice plate bore size in (inches)
Orifice plate reference temperature F (degrees Fahrenheit)
Pipe coefficient of thermal expansion in/in-F (inches per inch - Fahrenheit)
Pipe length ft (feet)
Back to top

Gas Units

The following units apply to GMR gas data items. Additional Shared Units apply to multiple data item types.

GMR Gas Item Description

GMR Units

Differential pressure inH2O (inches of water)
Energy MMBTU (million British thermal units)
Flow rate CFH (cubic feet per hour)
Flow temperature F (degrees Fahrenheit)
Flow time sec (seconds)
Heating value - Mass BTU/lb (British thermal units per pound)
Heating value - Volume BTU/CF (British thermal units per cubic foot)
Mass lb (pounds)
Static pressure psi (pound-force per square inch)
Uncorrected volume MCF (thousand cubic feet)
Volume MCF (thousand cubic feet)
Back to top

Liquid Units

The following units apply to GMR liquid data items. Additional Shared Units apply to multiple data item types.

GMR Liquid Item Description

GMR Units

Density lb/bbl (pounds per barrel)
Density pressure inH2O (inches of water)
Density temperature F (degrees Fahrenheit)
EVP (Equilibrium vapor pressure) psi (pound-force per square inch)
Gross standard volume (GSV) bbl (barrels)
Gross volume bbl (barrels)
Heating value - Mass BTU/lb (British thermal units per pound)
Heating value - Volume BTU/CF (British thermal units per cubic foot)
Indicated volume (IV) bbl (barrels)
K factor - Mass p/lbm (pulses per pound-mass)
K factor - Volume p/MMCF (pulses per million cubic feet)
Liquid volume bbl (barrels)
Mass lb (pounds)
Meter pressure psi (pound-force per square inch)
Meter temperature F (degrees Fahrenheit)
Standard volume bbl (barrels)
Odorized density lb/bbl (pounds per barrel)
Odorized volume bbl (barrels)
Reid vapor pressure psi (pound-force per square inch)
S&W percent (sediment & water percent) % (percent)
S&W volume (sediment & water volume) bbl (barrels)
Tank level ft (feet)
Uncorrected density lb/bbl (pounds per barrel)
Vessel draft level ft (feet)
Weight Klb (kilopounds)
Back to top

Shared Units

Some units are shared by multiple data items, such as gas configuration and gas metering, or gas items and liquid items. These units are included in the following table to identify units applicable to a variety of GMR data item types.

GMR Item Description

GMR Units

Gas composition % (percent)
Liquid concentration ppm (parts per million)
Viscosity lbm/fts (pounds per foot second)
Back to top

Unit Set Override

Unless you specify otherwise, FMS will apply the expected unit set to data coming into FMS via a GMR migration or via an FMS Legacy data group, even if it contains items with data units other than what is expected. To allow you to correct for this, FMS provides the option to specify a Unit set override to apply to the incoming GMR migration / FMS Legacy data instead.

The unit set override can be set in the following locations.

FMS Explorer

FMS Toolbox

FMS Scripting

Back to top