CygNet Measurement > FMS Explorer > Commands Menu > Running Estimate Station Data Commands

Running Estimate Station Data Commands

Note: This functionality is only available in systems licensed for FULL mode.

Station Estimation Use the Station Estimation button to access Estimate Station Data commands that trigger the service to perform station data estimates.

Station data that requires estimation can be missing, late, or of low data quality. Of these data types, late data estimation must be initiated by running the Estimate Station Data command, whereas missing data and low quality data is estimated as soon as the record enters the measurement system. The command triggers a search for station data that needs to be estimated, and the estimation engine associated with the Node defines what data will be estimated, and how to perform the estimation process.

See FMS Commands and Estimate Station Data for more information about this command.

See Scheduling FMS Command Tasks in the MSS for more information about scheduling commands.

See FMS ActiveX Controls and CxHmiFms for more information about using commands via FMS ActiveX controls on CygNet Studio or CygNet Vision screens.

See CxFms for more information about scripting commands.

Estimation Command Definition Properties

The following command definition properties apply to Estimation commands.

Property Description

Command type

For system commands, this property will be read-only and will display the selected command type.

See FMS Commands for more information about command types.

Priority

Select a processing queue Priority for the command from the drop-down menu.

Options from least to greatest priority are as follows.

  • Low level
  • Medium level
  • High level
  • User initiated transaction
  • Admin initiated transaction

Default value is Low level processing queue priority.

Logging

Select a Logging level for the command results from the drop-down menu.

Options are as follows.

  • Low - displays errors
  • Medium - displays errors and warnings
  • High - displays errors, warnings, and status

Default value is Low level logging when scheduling a command in the MSS.

Default value is High level logging when creating or running an ad-hoc command in FMS Explorer.

Estimation Command Parameters

Estimation rules must be defined prior to running an estimation command. Estimation rules are configured through the Admin menu. To configure estimation rules, or to delete them, see Managing Estimation Engines.

Managing Estimation Commands

Click Admin > Estimation on the Commands menu to access the Estimation Engines dialog box to add, edit, or delete estimation rules.

Back to top

Running an Estimation Command

Click Estimation on the Commands menu to access the Run FMS Command dialog box to run an Estimate Station Data command.

To Run an Estimation Command

  1. Open the Commands menu in FMS Explorer.
  2. Click Station Estimation to access the Run FMS Command dialog box.

    Run FMS Command

  3. Select a processing priority from the drop-down menu in the Command definition properties box. Options include Low, Medium, High, User, and Admin.
  4. Select a logging level from the drop-down menu in the Command definition properties box. Options include Low, Medium, and High.
  5. Define the command parameters. The parameters for the Estimate Station Data system command are too extensive to be described in the Command parameters box, so they are configured through the Estimation button on the Admin menu. See Managing Estimation Engines for more information.
  1. Click Run Command.
Back to top

Let us know how we can improve this topic.