Devices > Remote Devices > Emerson ROC EIE > FMS Config Data Group Mapping for Gas Meters

FMS Config Data Group Mapping for Gas Meters

The following table aligns "FMS Config" data items with the ROC protocol device data groups and elements they map to.

For more information, see EFM Data Items.

Data Group Element Description FMS Item String Native Data Group Native Data Group Element
cfg001 Meter Type eFMS_CFG_METER_TYPE Meter Config Parameters or AGA Gas/Flow Parms Multiple
cfg002 Primary Calc Method eFMS_CFG_CALC_METHOD_PRIMARY Meter Config Parameters or AGA Gas/Flow Parms Multiple
cfg003 Compressibility Calc Method eFMS_CFG_CALC_METHOD_FPV Meter Config Parameters or AGA Gas/Flow Parms Multiple
cfg007 Meter ID eFMS_CFG_METER_ID Meter Config Parameters or AGA Gas/Flow Parms PointTag
cfg008 Meter Description eFMS_CFG_METER_DESC Meter Config Parameters or AGA Gas/Flow Parms MtrRunID
cfg009 Contract Hour eFMS_CFG_CONTRACT_HOUR System Variables ContHour
cfg010 Base Pressure eFMS_CFG_BASE_PRESSURE Meter Config Parameters or AGA Gas/Flow Parms CntBsPress
cfg011 Base Temperature eFMS_CFG_BASE_TEMPERATURE Meter Config Parameters or AGA Gas/Flow Parms CntBsTemp
cfg012 * Meter Tube Inside Diameter * eFMS_CFG_METER_TUBE_INSIDE_DIAMETER * Meter Config Parameters or AGA Gas/Flow Parms PipeDiam
cfg013 Meter Tube Reference Temperature eFMS_CFG_METER_TUBE_REF_TEMP Run Parameters PipeTemp
cfg014 Meter Tube Material eFMS_CFG_METER_TUBE_MATERIAL Run Parameters PipeMat
cfg015 * Orifice Plate Bore Size * eFMS_CFG_ORIFICE_PLATE_BORE_SIZE * Meter Config Parameters or AGA Gas/Flow Parms OrfcDiam
cfg016 * Orifice Plate Reference Temperature * eFMS_CFG_ORIFICE_PLATE_REF_TEMP * Meter Config Parameters or AGA Gas/Flow Parms OrfcMesTem
cfg017 * Orifice Plate Material * eFMS_CFG_ORIFICE_PLATE_MATERIAL * Meter Config Parameters or AGA Gas/Flow Parms OrfcMat
cfg021 * DP Taps Type * eFMS_CFG_DP_TAPS_TYPE *

Meter Config Parameters or AGA Gas/Flow Parms

Tap
cfg022 SP Tap Location eFMS_CFG_SP_TAP_LOCATION Meter Config Parameters or AGA Gas/Flow Parms StPresV2
cfg023 SP Sensor Type eFMS_CFG_SP_SENSOR_TYPE Meter Config Parameters or AGA Gas/Flow Parms StPresV
cfg024 Atmospheric Pressure eFMS_CFG_ATMOSPHERIC_PRESSURE Run Parameters AtmPres
cfg025 Meter factor eFMS_CFG_METER_FACTOR Meter Config Parameters or AGA Gas/Flow Parms Fpwl
cfg026 **‡ K factor **‡

eFMS_CFG_GAS_K_FACTOR_VOLUME

(previously eFMS_CFG_K_FACTOR)

**‡
Meter Config Parameters or AGA Gas/Flow Parms LoDifforK
cfg030 Methane eFMS_CFG_METHANE Meter Config Parameters or AGA Gas/Flow Parms Methane
cfg031 Ethane eFMS_CFG_ETHANE Meter Config Parameters or AGA Gas/Flow Parms Ethane
cfg032 Propane eFMS_CFG_PROPANE Meter Config Parameters or AGA Gas/Flow Parms Propane
cfg033 Isobutane eFMS_CFG_ISOBUTANE Meter Config Parameters or AGA Gas/Flow Parms iButane
cfg034 n-Butane eFMS_CFG_N_BUTANE Meter Config Parameters or AGA Gas/Flow Parms nButane
cfg035 Isopentane eFMS_CFG_ISOPENTANE Meter Config Parameters or AGA Gas/Flow Parms iPentane
cfg036 n-Pentane eFMS_CFG_N_PENTANE Meter Config Parameters or AGA Gas/Flow Parms nPentane
cfg038 n-Hexane eFMS_CFG_N_HEXANE Meter Config Parameters or AGA Gas/Flow Parms nHexane
cfg039 n-Heptane eFMS_CFG_N_HEPTANE Meter Config Parameters or AGA Gas/Flow Parms nHeptane
cfg040 n-Octane eFMS_CFG_N_OCTANE Meter Config Parameters or AGA Gas/Flow Parms nOctane
cfg041 n-Nonane eFMS_CFG_N_NONANE Meter Config Parameters or AGA Gas/Flow Parms nNonane
cfg042 n-Decane eFMS_CFG_N_DECANE Meter Config Parameters or AGA Gas/Flow Parms nDecane
cfg043 Nitrogen eFMS_CFG_NITROGEN Meter Config Parameters or AGA Gas/Flow Parms Nitrogen
cfg044 Carbon Dioxide eFMS_CFG_CARBON_DIOXIDE Meter Config Parameters or AGA Gas/Flow Parms CarDio
cfg045 Water eFMS_CFG_WATER Meter Config Parameters or AGA Gas/Flow Parms Water
cfg046 Hydrogen Sulfide eFMS_CFG_HYDROGEN_SULFIDE Meter Config Parameters or AGA Gas/Flow Parms HydrSulf
cfg047 Hydrogen eFMS_CFG_HYDROGEN Meter Config Parameters or AGA Gas/Flow Parms Hydrogen
cfg048 Carbon Monoxide eFMS_CFG_CARBON_MONOXIDE Meter Config Parameters or AGA Gas/Flow Parms CarbMonox
cfg049 Oxygen eFMS_CFG_OXYGEN Meter Config Parameters or AGA Gas/Flow Parms Oxygen
cfg050 Helium eFMS_CFG_HELIUM Meter Config Parameters or AGA Gas/Flow Parms Helium
cfg051 ‡‡ Argon ‡‡ eFMS_CFG_ARGON ‡‡ Meter Config Params (Extra 107) ARGMP
cfg055 Heating Value - Volume eFMS_CFG_HEATING_VALUE_VOLUME Meter Config Parameters or AGA Gas/Flow Parms

HeatVal

+

HtVal

cfg056 Heating Value - Mass eFMS_CFG_HEATING_VALUE_MASS Meter Config Parameters or AGA Gas/Flow Parms

HeatVal

+

HtVal

cfg057 Heating Value Basis eFMS_CFG_HEATING_VALUE_BASIS

For 100, 107, and 500, MetCfg

For 300 and 400, RunParm

For MetCfg, CalcMeth2

For RunParm, CalcRaw

cfg058 Relative Density eFMS_CFG_RELATIVE_DENSITY Meter Config Parameters or AGA Gas/Flow Parms SpecGrav
cfg061 Viscosity eFMS_CFG_VISCOSITY Meter Config Parameters or AGA Gas/Flow Parms Viscos
cfg082 Isentropic Exponent eFMS_CFG_ISENTROPIC_EXPONENT Meter Config Parameters or AGA Gas/Flow Parms SpHtRatio
cfg086 Elevation eFMS_CFG_ELEVATION Meter Config Parameters or AGA Gas/Flow Parms Elevation
cfg089 * Low Flow Cutoff-Dp * eFMS_CFG_LOW_FLOW_CUTOFF_DP * Meter Config Parameters or AGA Gas/Flow Parms LoDifforK
cfg106 DP Alarm Low eFMS_CFG_DP_ALARM_LOW Unexposed data group Unexposed data group element
cfg107 DP Alarm High eFMS_CFG_DP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg108 SP Alarm Low eFMS_CFG_SP_ALARM_LOW Unexposed data group Unexposed data group element
cfg109 SP Alarm High eFMS_CFG_SP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg110 Temp Alarm Low eFMS_CFG_TEMP_ALARM_LOW Unexposed data group Unexposed data group element
cfg111 Temp Alarm High eFMS_CFG_TEMP_ALARM_HIGH Unexposed data group Unexposed data group element
cfg115 DP Calibrate Low eFMS_CFG_DP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg116 DP Calibrate High eFMS_CFG_DP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg117 SP Calibrate Low eFMS_CFG_SP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg118 SP Calibrate High eFMS_CFG_SP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg119 Temp Calibrate Low eFMS_CFG_TEMP_CALIBRATE_LOW Unexposed data group Unexposed data group element
cfg120 Temp Calibrate High eFMS_CFG_TEMP_CALIBRATE_HIGH Unexposed data group Unexposed data group element
cfg510 Latitude eFMS_CFG_LATITUDE Meter Config Parameters or AGA Gas/Flow Parms Latitude
cfg513 Sample Type eFMS_CFG_SAMPLE_TYPE Fixed Fixed

* Orifice

** Turbine

‡ K factor does not apply to 300 and 400 series devices.

‡‡ Applies only to 107 devices.

Back to top