The following tables list and describe the parameters specific to the UIS command component types for this remote device:
For more general information about UIS command component parameters, see UIS Command Components. The DG_F_DEV (Get data group from device) and DG_T_DEV (Send data group to device) command component types are configured in the template file. The other command component types are considered ‘special’ and are defined in the EIE editor code. See Special UIS Command Component Types for more information.
|
Update CygNet Point updates the record for a CygNet point. CYUPDTPT has the following command parameters:
|
|
Wait for CygNet Point signals the UIS to wait to perform a command until the value of the specified CygNet point changes to a specified value. CYWAITPT must be the first command component added to a UIS command. You cannot add other instances of CYWAITPT to a UIS command. CYWAITPT has the following command parameters:
|
Get data group from device retrieves a data group from a field device. The Parent XML Element is uccRecvParms. The following parameters are available for each specified data group type.
| Data Group Type | Parameter | Required | Description |
|---|---|---|---|
|
Date |
No |
History Date specifies the calendar day from which to collect historical data. Value options are floating-point numbers. |
|
|
EDate |
No |
End Date defines the ending date of a date-range request. Value options are floating-point numbers. |
|
|
IndexList |
No |
Index List Value options are strings. |
|
|
RqType |
Yes |
Request Type defines the specific request type for the data group. Value options are strings. |
|
|
SDate |
No |
Start Date defines the starting date of a date-range request. Value options are floating-point numbers. |
|
|
ZeroCount |
No |
Reset Log Index Value options are Boolean. |
|
|
Date |
No |
History Date specifies the calendar day from which to collect historical data. Value options are floating-point numbers. |
|
|
EDate |
No |
End Date defines the ending date of a date-range request. Value options are floating-point numbers. |
|
|
IndexList |
No |
Index List Value options are strings. |
|
|
RqType |
Yes |
Request Type defines the specific request type for the data group. Value options are strings. |
|
|
SDate |
No |
Start Date defines the starting date of a date-range request. Value options are floating-point numbers. |
|
|
Date |
No |
History Date specifies the calendar day from which to collect historical data. Value options are floating-point numbers. |
|
|
EDate |
No |
End Date defines the ending date of a date-range request. Value options are floating-point numbers. |
|
|
IndexList |
No |
Index List Value options are strings. |
|
|
RqType |
Yes |
Request Type defines the specific request type for the data group. Value options are strings. |
|
|
SDate |
No |
Start Date defines the starting date of a date-range request. Value options are floating-point numbers. |
|
|
ZeroCount |
No |
Reset Log Index Value options are Boolean. |
|
|
EDate |
Yes |
End Date defines the ending date of a date-range request. Value options are floating-point numbers. |
|
|
SDate |
Yes |
Start Date defines the starting date of a date-range request. Value options are floating-point numbers. |
|
|
ECDateTm |
Yes |
End Contract Date/Time defines the ending date and time of a date-range request for measurement history. Value options are strings in formats described in Selecting Date and Time. |
|
|
SCDateTm |
Yes |
Start Contract Date/Time defines the starting date and time of a date-range request for measurement history. Value options are strings in formats described in Selecting Date and Time. |
Send data group to device sends a data group to a field device. The parent XML Element is uccSendParms. The following parameters are available for each specified data group type.
| Data Group Type | Parameter | Required | Description |
|---|---|---|---|
|
DriftSpec |
No |
Allowed Minutes of Drift |