Use the CxFmsAlarmLogCtrl object to display and manipulate an ActiveX CygNet FMS Alarm Control in a CygNet Studio screen environment.
To see an example FMS Alarm Log control implemented in a pre-designed screen, open the FMS Alarm Ctrl.csf file in the CygNet\Clients\CStudio\Screens\Examples folder.
|
Sub btnApply_EventClick() Dim This : Set This = btnApply FmsAlarm.SessionNodeTag = editSessionNode.Text FmsAlarm.SessionBeginDate = editStartDate.Text FmsAlarm.SessionEndDate = editEndDate.Text FmsAlarm.SessionDateFormat = cboDateFormat.Selection FmsAlarm.PITDateTime = editPIT.Text FmsAlarm.UsePIT = checkUsePIT.Check FmsAlarm.Apply True End Sub
Sub btnCancel_EventClick() Dim This : Set This = btnCancel FmsAlarm.Cancel End Sub
Sub cboDateFormat_EventChange() Dim This : Set This = cboDateFormat FmsAlarm.SessionDateFormat = this.Selection End Sub
Sub checkUsePIT_EventChange() Dim This : Set This = checkUsePIT FmsAlarm.UsePIT = this.Check editPIT.Enable this.Check End Sub
Sub TheView_EventInitialize() Dim This : Set This = TheView editSessionNode.Text = FmsAlarm.SessionNodeTag
editStartDate.Text = FmsAlarm.SessionBeginDate editEndDate.Text = FmsAlarm.SessionEndDate cboDateFormat.AddString "Device" cboDateFormat.AddString "Contract" cboDateFormat.AddString "Local" cboDateFormat.Selection = FmsAlarm.SessionDateFormat
checkUsePIT.Check = FmsAlarm.UsePIT editPIT.Text = FmsAlarm.PITDateTime editPIT.Enable = FmsAlarm.UsePIT End Sub |