Scripting > CxHmiFms > CxFmsDashboardCtrl Object > CxFmsDashboardCtrl Properties

CxFmsDashboardCtrl Properties

The CxFmsDashboardCtrl object contains the following properties.

Note: Time format selection is not available in this control. The Dashboard control displays data in Contract time (C).

General Properties

Browse by letter:     A     B     C     D     E     F             P     R     S     U     V

Property SubType Read Only Description

Appearance

Integer

No

Returns/sets the appearance of the object boundary. Possible values for this property are as follows.

  • 0 – Flat
  • 1 – 3D

Default value is 0 - Flat

AttributeDisplaySettingsXml

String

No

Returns/sets the XML specifying the colors and cell values that will appear on the FMS Dashboard control.  Another way to configure this property is to use the OCX Properties dialog box (click the Dashboard page, then click Configure display properties).

See Configuring Dashboard Display Properties for more information about display settings.

BeginDate

String

No

Returns/sets the starting date of the FMS Dashboard control.

This string can be in one of the following forms.

  • Absolute date, for example, 1/31/2019
  • Relative date, for example, T (today), T-14 (14 days prior to today), or T+1 (one day following today)

Note: This property is only used if the UseSessionOptions property is set to 0 - No.

Default value is T-7

BorderStyle

Integer

No

Returns/sets the border style. Possible values for this property are as follows.

  • 0 - None
  • 1 - Fixed single border

Default value is 0 - None

ChooserAllowMultiSelect

Boolean

No

Returns/sets whether or not the user can select multiple Nodes in the Node chooser. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ChooserFilterString

String

No

Returns/sets the filter to be used when retrieving Nodes.  Wildcard values * (multiple character) and ? (single character) are supported. Wildcards can be used in any part of the string to specify that any character or set of characters is allowed in its place.

Example

A filter string of "*Test*" will retrieve all Nodes with the word "Test" somewhere in the string, such as "TestDevice" or "MyTestDevice" or "Device001Test".

Default value is * (multiple character wildcard)

ChooserFilterType

Integer

No

Returns/sets the Node property that will be filtered by the string specified in the ChooserFilterString property. Possible values for this property are as follows.

  • 0 – Name
  • 1 – Description
  • 2 – ID

Default value is 0 - Name

ChooserGroupSelection

String

No

Returns/sets the group currently selected in the Node chooser’s Group combo box.

ChooserNodeCategorySelection

Integer

No

Returns/sets the Node category currently selected in the Node chooser’s Node category combo box. Possible values for this property are as follows.

  • 6 - <Any>
  • 2 – Group
  • 1 - Device
  • 8 – Gas Device
  • 9 - Liquid Device
  • 3 – Station

Default value is 6 - <Any>

ChooserNodeCategoryVisible

Boolean

No

Returns/sets whether or not the Node chooser’s Node category combo box is visible. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ChooserPrimarySortColumn

Integer

No

Returns/sets the primary sort column of the Node chooser’s Node list.

Possible values for this property are as follows.

  • 0 - Type ascending
  • 2 - Name ascending
  • 3 - Description ascending
  • 4 - Type descending
  • 5 - Name descending
  • 6 - Description descending

Default value is 2 - Name ascending

ChooserSiteServiceSelection

String

No

Returns/sets the Site.Service currently selected in the Node chooser’s FMS service combo box.

ChooserSiteServiceVisible

Boolean

No

Returns/sets whether or not the Node chooser’s FMS service combo box is visible. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

CmdDefinitionXml

String

No

Returns/sets the XML specifying the custom FMS commands configured for the control.  Another way to configure this property is to use the OCX Properties dialog box (Command page).

ColumnsXml

String

No

Returns/sets the XML specifying the columns that will appear on the FMS Dashboard control. 

Another way to configure this property is to use the control-specific property page in the CygNet FMS Control Properties dialog box. See CygNet FMS Dashboard Control for more information.

CustomColumnsUpdateInterval

Integer

No

Returns/sets the update interval, in number of seconds, for the custom data columns, as configured in the Admin Options, if displayed in the Dashboard control.

See Using the Dashboard Control for more information.

DataMode

Integer

No

Returns/sets the data mode for viewing summary data. Possible values for this property are as follows.

  • 1 – Device_Mode
  • 3 – Station_Mode

Default value is 1 - Device_Mode

DateTimeDisplayMode

Integer

No

Returns/sets whether dates displayed in the FMS Dashboard control will have the time appear before the date (leading) or after the date (trailing). Possible values for this property are as follows.

  • 0 – Leading time
  • 1 – Trailing time

Default value is 0 - Leading time

EndDate

String

No

Returns/sets the ending date of the FMS Dashboard control. This string can either be in the form of an Absolute date, for example, 1/31/2019, or a Relative date, for example, T (today), T-14 (14 days prior to today), or T+1 (one day following today).

Note: This property is only used if the UseSessionOptions property is set to 0 - No.

Dault is T

FilterConfigXml

String

No

Returns/sets the XML specifying the filter for the data that will be displayed in the FMS Dashboard control.  Another way to configure this property is to use the OCX Properties dialog box (click the Dashboard tab, then Filter). 

See Configuring Dashboard Filters for more information about the filter settings.

Font

StdFont

No

Returns/sets the font used by the FMS Dashboard control. Click to access the Font dialog box to make font selections.

Default value is MS Shell Dlg.

PITDateTime

String

No

Returns/sets the Point in Time date and time of the FMS Dashboard control. 

This string can be in one of the following forms.

  • Absolute Date/Time (for example, 1/31/2019 7:10:14 AM)
  • Relative Date/Time (for example, y-1 m-2 d=15 H=5 M=30 S=0)
  • Relative Day, which is an offset from the current day T (for example, T-10)

Default value is T, date and time today.

See Using the Home Menu for more information about PIT mode.

Note: This property is only used if the UsePIT property is set to 1 - Yes.

RecordOrder

Integer

No

Returns/sets the order in which records will be displayed in the FMS Dashboard. Possible values for this property are as follows.

  • 0 - Oldest _First
  • 1 - Newest_First

Default value is 0 - Oldest_First

SessionNodeClickOption

Integer

No

Returns/sets selection behavior for setting the Session Node in the FMS History Grid. Possible values for this property are as follows.

  • 0 - SingleClick
  • 1 - DoubleClick

Default value is 1 - DoubleClick

SessionBeginDate

String

No

Returns/sets the Session starting date for the time window displayed in the control.  This string can either be in the form of an Absolute date, for example, 1/31/2019, or a Relative date, for example, T (today), T-14 (14 days prior to today), or T+1 (one day following today).

Note: This property is only used if the UseSessionOptions property is set to 1 - Yes.

Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control.

SessionEndDate

String

No

Returns/sets the Session ending date for the time window displayed in the control. This string can either be in the form of an Absolute date, for example, 1/31/2019, or a Relative date, for example, T (today), T-14 (14 days prior to today), or T+1 (one day following today).

Note: This property is only used if the UseSessionOptions property is set to 1 - Yes.

Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control.

SessionNodeTag

String

No

Returns/sets the Session Node tag, which specifies the active Node in the FMS Configuration control.  This tag must be in the form SITE.SERVICE|ID (for example, TEST.FMS|2540).

Note: This property is only used if the UseSessionOptions property is set to 1 - Yes.

Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control.

ShowChooserPane

Boolean

No

Returns/sets whether or not the Chooser pane will be displayed in the control.

Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ShowCustomColumns

Boolean

No

Returns/sets

whether to show custom columns, as configured in the Admin Options (Custom Dashboard Columns page), in the CygNet FMS Dashboard Control.

Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

ShowExceptionCount

Boolean

No

Returns/sets whether or not the FMS Dashboard control will display a fixed column showing the number of exceptions for a Node. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ShowNodeDescription

Boolean

No

Returns/sets whether or not the FMS Dashboard control will display a fixed column showing the Node description. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ShowNodePriority

Boolean

No

Returns/sets whether or not the FMS Dashboard control will display a fixed column showing the Node priority. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

ShowOptionsPane

Boolean

No

Returns/sets whether or not the Options pane will be displayed in the control.

Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ShowPercentMissing

Boolean

No

Returns/sets whether or not the FMS Dashboard control will display a fixed column showing the percentage of missing data for a Node.  "Missing data" means records with a collection status of anything other than Good or Partial. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

ShowUseFilterButton

Boolean

No

Returns/sets whether or not the FMS Dashboard control will display the Use filter button in the control. 

Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 1 - Yes

UseFilterConfig

Boolean

No

Returns/sets whether or not to use the configured filter values (FilterConfigXml) to determine what data to display in the control.

Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

UsePIT

Boolean

No

Returns/sets whether or not the PITDateTime property will be used. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

UseSessionNode

Boolean

No

Returns/sets whether or not the SessionNodeTag property will specify the active Node in the FMS Dashboard control.  If this property is set to 0 - No, the FMS Dashboard control will present a Chooser page for selection of the active Node. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

UseSessionOptions

Boolean

No

Returns/sets whether or not the SessionBeginDate and SessionEndDate properties will be used in place of the BeginDate and EndDate properties. Possible values for this property are as follows.

  • 0 - No
  • 1 - Yes

Default value is 0 - No

VisibleAttribute

Integer

No

Returns/sets the data view that will be displayed in the FMS Dashboard control. 

When the DataMode property is set to Device, the available options for the data view will be as follows.

  • 0 – DataQuality
  • 1 – HasConfig
  • 2 – OpenExceptions
  • 3 – LinkExceptions
  • 4 – EditState
  • 5 – CollectStatus
  • 6 - CollectStatusDetail
  • 7 - ExportStatus
  • 8 - AnalystOverview

Default value is 0 - DataQuality

When the DataMode property is set to 3 - Station_Mode, the available options for the data view will be as follows.

  • 0 – DataQuality
  • 2 – OpenExceptions
  • 4 – EditState
  • 8 - AnalystOverview

Default value is 0 - DataQuality

Back to top