The Headers page of the well test configuration control defines the list of headers included in each well test configuration. Each header corresponds to a separator facility, and this is where you define its point tag, properties, and the associated wells. The page consists of the following sections:
Click the following image for more information:
| Sample Headers Page Configuration |
To configure Well Test Headers
Perform the following steps to configure the headers properties, referring to the property definitions below:
The Headers section of the Headers page defines the headers to be included in each well test operation.
| Property | Description | XML |
|---|---|---|
|
Tag |
Specifies the fully qualified facility tag of the well test header facility in the format: site.service::facility_id. |
|
|
Add header |
|
|
|
Delete header |
|
Note:
The columns in the Headers grid can be filtered.
The Properties section of the Headers page defines the general properties of each header included in the well test operation.
| Property | Description | XML |
|---|---|---|
|
Tag |
Specifies the fully qualified facility tag of the well test header facility in the format: site.service::facility_id. |
|
|
Description |
Specifies the description of the well test header facility retrieved from the Facility service. |
|
|
Enabled |
Indicates whether the header is enabled. Options include True or False. |
|
|
Template |
Specifies the name of the header template to use for this header, which must match a defined header template name. The header template name, type, queue UDC, valve positions, and related commands are defined in the <HeaderTemplate> element. More than one header can use the same template. |
The Wells section of the Headers page defines the wells associated with each header. Each well is associated with a facility tag and position number. Only enabled wells will be tested.
| Property | Description | XML |
|---|---|---|
|
Position |
Specifies the position number for the well. This must line up with one of the positions in the associated header template. Values include 1, 2, 3, …, n. |
|
|
Description |
Specifies the description of the well facility retrieved from the Facility service. |
|
|
Tag |
Specifies the fully qualified facility tag of the well in the format: site.service::facility_id. E.g., MYSITE.UIS::AMANDA_WL. |
|
|
Enabled |
Specifies whether the well can be tested. While it is possible for the header queue to contain wells that are disabled, only enabled wells will be tested. When a well is read from the top of the header queue, prior to testing, the enabled attribute will be read.
Note: Make sure you read the definition for the enabledUdc attribute for further usage notes on the enabled attribute. Options include True or False. |
|
|
Enabled UDC |
The Enabled UDC property (enabledUdc) allows the configuration of the Enabled (enabled) property by point. The defined UDC will be combined with the facility tag to formulate a point. The Enabled UDC Property /enabledUdc attribute takes precedence over the Enabled (enabled). Click the browse button to open the Select UDC dialog box and select an appropriate UDC.
Note: This attribute allows manipulation of a well's enabled/disabled status external to the Canvas Well Test Status screen, and the CygNet Well Test Module. |
|
|
Add well |
|
|
|
Delete well |
|
Note:
The columns in the Wells grid can be filtered.