NameDescriptionTypeAdditional information
beginActiveDate

(Optional) Begin Active Date

date

None

endActiveDate

(Optional)End Active Date

date

None

name

(Optional)Device Name

string

None

description

(Optional)Device Description

string

None

siteService

(Optional)CygNet Site.Service of the device

string

None

facilityId

Facility Id of the device

string

None

sortPriority

(Optional)Sort priority of the device

integer

None

securityApp

Security application of the device

string

None

daysOfData

(Optional)Number of days for which the source device associated with the Node will retain data

integer

None

deviceInstallDate

(Optional)Install date of the device

date

None

pMRecordSpan

(Optional)Periodic metering record span(in minutes)

RecordSpan

None

pQRecordSpan

(Optional)Periodic quality record span (in minutes)

RecordSpan

None

collectionMethod

(Optional)Collection method of the device

CollectionMethod

None

stationType

(Optional)Station type of the meter

StationType

None

stationContribution

(Optional)Station contribution of the meter

StationContribution

None

timezoneKey

(Optional)CygNet Timezone key

integer

None

timezoneDst

(Optional)Daylight saving time status of the device

boolean

None

contractHour

(Optional)Contract hour of the device

byte

None

stationValidationNodeId

(Optional)Node ID of the linked station of the meter

integer

None

stationValidationNodeName

(Optional)Node Name of the linked station of the meter

string

None

isActive

(Optional)Active status of the device

boolean

None

hasConfig

(Optional)Configuration status of the device

boolean

None

hasPMHistory

(Optional)Periodic metering status of the device

boolean

None

hasPQHistory

(Optional)Periodic quality status of the device

boolean

None

hasEvents

(Optional)Events status of the device

boolean

None

hasAlarms

(Optional)Alarms status of the device

boolean

None

useAlternateSource

(Optional)Flag to determine if the device uses another Node as the source

boolean

None

deviceType

(Optional)Device type

integer

None

pollingSiteService

(Optional)Polling CygNet Site.Service

string

None

pollingFacilityId

Polling Facility Id

string

None

gmrUnitSetId

(Optional)GMR UnitSet Id

integer

None

hasBatchHistory

(Optional)Batch status of the device

boolean

None

hasTicketHistory

(Optional)Ticket status of the device

boolean

None

alternateSourceNodeName

Node name used as the alternate source of the device

string

None

hasProduct

(Optional)Liquid product status of the device

boolean

None

useJobScheduleStartDate

(Optional)Flag to use Job Schedule Start Date

boolean

None

jobScheduleStartDate

(Optional)Job Schedule Start Date

date

None