Editable Data Items - Gas
Data items for gas devices or stations can be edited directly from the History Grid as indicated with check marks in the following table.
Note: Some data that cannot be edited directly (e.g. Data Source, GQ Source) can be updated in the grid as a result of edits performed on associated data or properties. See Data Source in the CygNet Measurement Concepts topic for more information.
| Data Item Column |
Editable for Gas Devices |
Editable for Gas Stations |
Description |
|---|---|---|---|
| Volume |
|
|
Volume
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| Energy |
|
|
Energy
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| Mass |
|
|
Mass
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| VCF |
|
N/A | Volume Correction Factor See VCF in the CygNet Measurement Concepts topic for more information about this factor. |
| Discharge coefficient |
|
N/A | Discharge Coefficient |
| Diff Pressure |
|
N/A | Differential pressure |
| Static Pressure |
|
|
Static pressure |
| Flow Temp |
|
|
Flow temperature |
| Flow Time |
|
N/A | Flow time
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| Flow Rate |
|
N/A | Flow rate |
| Pulse Count |
|
N/A | Pulse count
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| Uncorrected Volume |
|
N/A | Uncorrected volume
Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| IV |
|
N/A | Integral Value
See Creating or Editing Configuration Log Entries for more information about how this value is calculated for orifice meters. (For turbine meters that return IV, pulse count is used when IV is not returned.) Note: Data-spreading calculation functionality can apply to this data item. See CygNet Measurement Data Calculation for more information. |
| Integral Multiplier Value |
|
N/A | Integral Multiplier Value, IMV |
| K Factor Volume |
|
- | K factor - Volume |
| K Factor Mass |
|
- | K factor - Mass |
| Meter Factor |
|
- | Meter factor |
| Methane |
|
|
C1 |
| Ethane |
|
|
C2 |
| Propane |
|
|
C3 |
| Isobutane |
|
|
isoC4 |
| n-Butane |
|
|
C4 |
| Isopentane |
|
|
isoC5 |
| n-Pentane |
|
|
C5 |
| Neopentane |
|
|
neoC5 |
| n-Hexane |
|
|
C6 |
| n-Heptane |
|
|
C7 |
| n-Octane |
|
|
C8 |
| n-Nonane |
|
|
C9 |
| n-Decane |
|
|
C10 |
| Nitrogen |
|
|
N2 |
| Carbon Dioxide |
|
|
CO2 |
| Water |
|
|
H2O |
| Hydrogen Sulfide |
|
|
H2S |
| Hydrogen |
|
|
H2 |
| Carbon Monoxide |
|
|
CO |
| Oxygen |
|
|
O2 |
| Helium |
|
|
HE |
| Argon |
|
|
AR |
| Heating Value Volume |
|
|
Heating value volume |
| Heating Value Mass |
|
|
Heating value mass |
| Relative Density |
|
|
Relative density |
| Compressibility |
|
|
Compressibility |
| Dew Point |
|
|
Dew point |
| Viscosity |
|
|
Viscosity |