LogManager Methods
The LogManager methods can be used with event options in scripted CygNet Studio screens to assist with script profiling. LogManager works in conjunction with the LOGMASK.SCRIPT keyword in the HSS configuration file. See HSS Profiling or CygNet Studio Profiling for more information.
The LogManager object contains the following methods:
GetProfiler
The GetProfiler method writes a profile message to the scripting log file. Returns an object that logs a profile timing message on creation and deletion (object goes in or out of scope). On creation PROFILE_MAX must be set and on deletion (object goes out of scope) PROFILE_MIN must be set.
Syntax
GetProfiler()
Example
LogAll
The LogAll method writes the message string to the scripting log file.
Syntax
LogAll(Message As String)
Parameters
| Parameter |
Required |
Description |
|---|---|---|
| Message | Y | Logs all messages regardless. |
Example
LogMax
The LogMax method writes the message string to the scripting log file if MAX_TRACE is set in the HSS service configuration file.
Syntax
LogMax(Message As String)
Parameters
| Parameter |
Required |
Description |
|---|---|---|
| Message | Y | Logs the message if MAX_TRACE is set. |
Example
LogMin
The LogMin method writes the message string to the scripting log file if MIN_TRACE is set in the HSS service configuration file.
Syntax
LogMin(Message As String)
Parameters
| Parameter |
Required |
Description |
|---|---|---|
| Message | Y | Logs the message if MIN_TRACE is set. |