Ferguson Beauregard Net EIE

Although Ferguson Beauregard Auto-Cycle Plus and SFC are not Modbus devices, the EIE contains a data group ("FCU Modbus Setup") that allows basic process variables to be passed through to another flow control device. This operation requires that you select a device type and Modbus address, define the data and registers, and set up Modbus communication options. This information is read only and must be configured on the device during device installation.

Another feature of this EIE is its support for gas flow data and calculations using the "Gas Measurement Config" data group. The Auto-Cycle Plus device is not intrinsically configured to provide gas flow data, so CygNet developed a data group that extracts the required data and performs gas flow calculations with it.

Specifications

The following table lists and describes EIE specifications.

Manufacturer

Ferguson Beauregard

Protocol(s)

FB Net

Model(s)

Ferguson Beauregard Auto-Cycle Plus (TD, V4 RTU5000, and V5)

Ferguson Beauregard CBM-POD

Ferguson Beauregard CBM-WellHead (RTU5000 and TD)

Ferguson Beauregard SFC

Required Files

CxDdsFbNetEditors.dll

UisFbNetDriver.dll or UisFbNetDriver64.dll

Sample Templates

FbNet_ACP_TD.dtf

FbNet_ACP_V4_RTU5000.dtf

FbNet_ACP_V5.dtf

FbNet_CBM_Pod.dtf

FbNet_CBM_WellHead_RTU5000.dtf

FbNet_CBM_WellHead_TD.dtf

FbNet_SFC.dtf

eieType

FbNet

Cryout Support

No

FMS Support

No for SFC

Yes, for all models except SFC, using FMS Legacy EFM data items.

Note: In cases where only GMR support was previously available, CygNet Measurement now provides equivalent data support using FMS Legacy data items. If you were previously using GMR data items, you must update to use FMS Legacy data items, effective with the CygNet v8.5.0 release. Update options are provided as part of your corresponding software upgrade procedure.

Listen Mode

No

64-bit Support

Yes. See 64-bit Device Drivers.

For more information, see sample device template files and manufacturer documentation.


More:

Back to top