CxFmsRawDeviceDataCtrl Properties
The CxFmsRawDeviceDataCtrl object contains the following properties.
General Properties
Browse by letter: [A] [B] [C] [D] [E] [F] [P] [S] [U]
| Property | SubType | Read Only | Description |
|---|---|---|---|
|
Integer |
No |
Returns/sets the appearance of the object boundary Possible values for this property are as follows.
Default value is 0 - Flat. |
|
|
String |
No |
Note: This property is only used if the UseSessionOptions property is set to 0 - No. Returns/sets the starting date of the FMS Raw Data control This string can be in one of the following forms.
Default value is T-7. See Selecting Date and Time for more information. Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
Integer |
No |
Returns/sets the border style Possible values for this property are as follows.
Default value is 0 - None. |
|
|
String |
No |
Returns/sets the filter to be used, of the type specified by the ChooserFilterType property, when retrieving Nodes for selection Wildcard values * (multiple character) and ? (single character) are supported. Wildcards can be used in any part of the string to specify that any character or set of characters is allowed in its place. ExampleA filter string of "*Test*" will retrieve all Nodes with the word "Test" somewhere in the string, such as "TestDevice" or "MyTestDevice" or "Device001Test". Default value is * (multiple character wildcard). |
|
|
Integer |
No |
Returns/sets the Node property type that will be filtered by the string specified in the ChooserFilterString property Possible values for this property are as follows.
Default value is 0 - Name. |
|
|
String |
No |
Returns/sets the group currently selected in the Node chooser’s Group combo box |
|
|
Integer |
No |
Returns/sets the Node category currently selected in the Node chooser’s Node category combo box Possible values for this property are as follows.
Default value is 1 - Node_Category5_Device. |
|
|
Boolean |
No |
Returns/sets whether or not the Node chooser’s Node category combo box is visible Possible values for this property are as follows.
Default value is 1 - Yes. |
|
|
Integer |
No |
Returns/sets the primary sort column of the Node chooser’s Node list Possible values for this property are as follows.
Default value is 2 - Name ascending. |
|
|
String |
No |
Returns/sets the Site.Service currently selected in the Node chooser’s FMS combo box |
|
|
Boolean |
No |
Returns/sets whether or not the Node chooser’s FMS combo box is visible Possible values for this property are as follows.
Default value is 1 - Yes. |
|
|
String |
No |
Returns/sets the XML specifying the custom FMS commands configured for the control Another way to configure this property is to use the control’s property page. |
|
|
String |
No |
Returns/sets the XML specifying the columns that will be displayed in the FMS Raw Data control Another way to configure this property is to use the control-specific property page in the CygNet FMS Control Properties dialog box. See CygNet FMS Raw Data Control for more information. |
|
|
Integer |
No |
Returns/sets the "Data view" option that will be displayed in the FMS Raw Data control [supersedes the deprecated DisplayMode property] Possible values for this property are as follows.
Default value is 1 - AlarmEntry. |
|
|
Integer |
No |
Note: This property is only used if the UseSessionOptions property is set to 0 - No. Returns/sets the format of the dates shown in the FMS Raw Data control Possible values for this property are as follows.
Default value is 0 - Device_Time . Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
Integer |
No |
Returns/sets the number of decimal places that will be shown in the values displayed by the FMS Raw Data control Acceptable values include 0 - 10 decimal places. Default value is 7. |
|
|
DisplayMode |
Integer |
No |
Note: This property deprecated in favor of DataView
Returns/sets the "Data view" option that will be displayed in the FMS Raw Data control See DataView for details. |
|
String |
No |
Note: This property is only used if the UseSessionOptions property is set to 0 - No. Returns/sets the ending date of the FMS Raw Data control This string can be in one of the following forms.
Default value is T. See Selecting Date and Time for more information. Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
StdFont |
No |
Returns/sets the font used by the FMS Raw Data control Click … to access the Font dialog box to make font selections. Default value is MS Shell Dlg. |
|
|
String |
No |
Note: This property is only used if the UsePIT property is set to 1 - Yes. Returns/sets the Point in Time date and time of the FMS Raw Device Data control This string can be in one of the following forms.
Default value is T, date and time today. See Using the Home Menu for more information about PIT mode. |
|
|
String |
No |
Note: This property is only used if the UseSessionOptions property is set to 1 - Yes. Returns/sets the Session starting date for the time window displayed in the control This string can be in one of the following forms.
See Selecting Date and Time for more information. Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
Integer |
No |
Note: This property is only used if the UseSessionOptions property is set to 1 - Yes. Returns/sets the Session date/time format for the time window displayed in the control Possible values for this property are as follows.
Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
String |
No |
Note: This property is only used if the UseSessionOptions property is set to 1 - Yes. Returns/sets the Session ending date for the time window displayed in the control This string can be in one of the following forms.
See Selecting Date and Time for more information. Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
String |
No |
Note: This property is only used if the UseSessionNode property is set to 1 - Yes. Returns/sets the Session Node tag, which specifies the active Node in the FMS Raw Data control This tag must be in the form SITE.SERVICE|ID (for example, TEST.FMS|2540). Note: Because Session options are universal to all FMS controls, this property can only be set via script during runtime, and the value is not saved to the control. |
|
|
Boolean |
No |
Returns/sets whether or not the Chooser pane will be displayed in the control Possible values for this property are as follows.
Default value is 1 - Yes. |
|
|
Boolean |
No |
Returns/sets whether or not to show only the most recent record for each hour in the control Possible values for this property are as follows.
Default value is 1 - Yes. |
|
|
Boolean |
No |
Returns/sets whether or not the Options pane will be displayed in the control Possible values for this property are as follows.
Default value is 1 - Yes. |
|
|
Boolean |
No |
Returns/sets whether or not units will be displayed in the FMS Raw Data control Possible values for this property are as follows.
Default value is 0 - No. |
|
|
String |
No |
Returns/sets the unit set used to determine the units of each FMS data item in the FMS Raw Data control Another way to configure this property is to use either the control’s property page or to use the Options page on the FMS Raw Data control. Default value is the <Default> unit set |
|
|
Boolean |
No |
Returns/sets whether or not the PITDateTime property will be used Possible values for this property are as follows.
Default value is 0 - No. |
|
|
Boolean |
No |
Returns/sets whether to use the SessionNodeTag property [if set to 1 - Yes] or to present a Chooser page for Node selection [if set to 0 - No] to specify the active Node in the control Possible values for this property are as follows.
Default value is 1 - Yes for this control. Note: Default value varies by control type. |
|
|
Boolean |
No |
Returns/sets whether to use the SessionBeginDate, SessionEndDate, and SessionDateFormat properties [if set to 1 - Yes] in place of the BeginDate, EndDate, and DateFormat properties [if set to 0 - No] Possible values for this property are as follows.
Default value is 1 - Yes for this control. Note: Default value varies by control type. |