SleepTimerActions
The Monitor or Test action types support the configuration of sleep time action(s) to specify how long the Test or Monitor action type will "sleep" before updating the actual timeout value and evaluating the conditional expression. If any actions are specified for the Sleep time actions, then for every sleeptime timeout specified, those actions will be executed. For example, wait five seconds and then poll the device. In the XML configuration these conditional actions are specified in the <SleepTimerActions> element.
To learn about how these elements relate to other elements in a well test configuration XML structure, see Well Test Hierarchy.
Example
|
<Action type="Test" timeoutValue="TMWTTGT" timeoutValueType="UDC" timeoutValueUpdate="True" timeoutRelativeFacilityLink="" timeoutActualUdc="TMWTACT" udc="POMSV" operator="=" value="1000" conditionRelativeFacilityLink="Separator" sleeptime="5000"> <SleepTimerActions> <Action type="UisCommand" command="POLL" relativeFacilityLink="Separator" statusUDC="SYCMDSTAT"> <Parameters /> </Action> </SleepTimerActions> </Action>
<Action …> <SleepTimerActions> <Action type="UisCommand" command="POLL" relativeFacilityLink="Separator" statusUDC="SYCMDSTAT" /> <Action type="PointValueCompare" operator="<>" value1="POMSV" value1type="UDC" value1relativeFacilityLink="Separator" value2="1" value2type="SELF" value2relativeFacilityLink=""> <TrueAction> <!-- Position moved...need to stop test - and alarm out--> <Action type="Exit" udc="MSG" relativeFacilityLink="Separator" valueType="Text" attribute="" value="Position Moved" /> </TrueAction> <FalseAction> </FalseAction> </Action> </SleepTimerActions> </Action> |
Properties
The <SleepTimerActions> element has the following properties:
| Property | Description |
|---|---|
|
Case Sensitive |
Yes |
|
Required |
Yes |
|
Number of Instances Allowed |
1 |
|
Parent Element |
<Action> |
|
Child Elements |
<Action> |
|
Attributes |
None |
Attributes
The <SleepTimerActions> element has no attributes.